Verify that the digital signage plug-in process is running
Prerequisites:
- The Digital Signage plug-in is installed and configured.
- MediaCenter is set up and configured.
- Start IIS and AtHocDeliveryServices.
- Verify in theBlackBerry AtHocmanagement system that theNDSserver and details about theNDSserver for Digital Signage are correct.
- Publish an alert to a digital sign.
- Verify the details of the alert in the mediaCenter.
The format of the alert message sent to media center is:
Alert|Alert ID| Alert Title | Alert Text | Target URL | Status | Color | Site | Zone | Building | Floor |Duration
where:
- Alert ID: TheNDStask ID.
- Alert Title: Title or custom title of the alert.
- Alert Title: Body or custom body of the alert.
- Target URL: This value is empty during alert creation and termination.
- Status: During alert creation, the status is 1. During alert termination, the status is 0.
- Color: The color is based on the alert severity. See Display text color to alert severity mapping.
- Site:AtHoc.
- Zone: The address specified as the mass device end point in theBlackBerry AtHocmanagement system. For example, if the address isdefault:0, then the value is0.
- Building: This value is empty during alert creation and termination.
- Duration: The alert display time in seconds. This value is empty during alert termination.