HKEY_LOCAL_MACHINE\SOFTWARE\Athoc Telephony Service\VoiceDetection
The following changes are needed for this registry:
TAS
2.5.1 UpdatesWhen upgrading from
TAS
2.5 to TAS
2.5.1, in each application server, merge the AtHocTelephonyService.251upgrade.reg
file in the package. This step adds the following two registry entries with default values:- vmEndingSilenceNoBeepMS=3000(in milliseconds): The period of silence during which the voice mail is detected. Although a beep is not heard, the delivery service plays the voice mail message.
- vmEndingSilencePercent=90 (percentage): The minimum percentage of silence frames allowed for eithervmEndingSilenceMSorvmEndingSilenceNoBeepMSparameters.
The following image shows the list of registry parameters with their default values: 

TAS
2.5 UpdatesWhen upgrading from
TAS
2.4 to TAS
2.5, manually go through the checklist on each application server and ensure the following parameter values are set correctly:- min1PeakThreshold = 35
- min2PeaksThreshold = 50
- vdLog = 0
- vdTimeout = 3 (was 2)
- vmDetectionTimeoutMS = 25000 (or larger)